Simco FMX-002 Electrostatic Fieldmeter is a specialized handheld instrument designed to locate and measure electrostatic charge potentials in industrial and laboratory environments. While succeeded by newer models like the FMX-003 and FMX-004, the FMX-002 remains a benchmark for precision in electrostatic discharge (ESD) management. 1. Core Functionality and Measurement The FMX-002 is primarily used to quantitatively assess the strength and distribution of static charges on surfaces. Measurement Range : It detects static voltages up to (19.99 kV) for both positive and negative polarities. Dual Range Accuracy : The device features auto-ranging capabilities with a low range (0 to ±1.49 kV) and a high range (up to ±20 kV), maintaining an accuracy of Ion Balance Testing : By attaching a specialized metal plate, the meter can also measure an ionizer's offset voltage (ion balance) up to 2. Operational Procedures Effective use of the FMX-002 requires specific positioning and grounding to ensure reliable data. Calibration of Distance : Accurate readings depend on maintaining a distance of exactly 25 mm (1 inch) from the test surface. The FMX-002 uses two LED guide ring lights to assist; when the two light beams overlap into concentric circles, the device is at the correct distance. : The conductive resin (ABS) case must be grounded using a supplied grounding lead to drain any existing charges and provide a proper reference point for measurement. Zeroing the Meter : Before each measurement, the sensor should be turned toward an uncharged area and the ZERO button pressed to reset the reading. 3. Interface and Display Features The device is designed for high readability, featuring both digital and graphical feedback. Visual Indicators : Results are shown numerically on an LCD alongside a color-coded bar graph: indicates positive polarity, while represents negative polarity. Hold Function : A dedicated HOLD button allows users to retain a reading on the screen, which is useful when the display is difficult to see during the actual measurement process. Power Management : To preserve its 9V battery, the meter includes an auto-off feature that shuts the device down after approximately five minutes of inactivity. 4. Maintenance and Troubleshooting To maintain precision, the sensor—which is the most sensitive part of the instrument—must be kept free of contaminants like water, oil, or solvents. Operation/Maintenance FMX-003 Electrostatic Fieldmeter

Simco FMX-002 is a legacy handheld electrostatic field meter primarily used for locating and measuring static charges in industrial environments. While it has been largely superseded by the , it remains a reliable tool for basic static monitoring and ionizer balance testing. Micro Precision Calibration ⚡ Quick Specs Measurement Range: plus or minus 1.49 kV (Low) and plus or minus 1.0 plus or minus 20.0 Accurate at exactly 25mm (approx. 1 inch) from the target Visual Aid: Features two LED guide lights that overlap when at the correct distance Data Display: 3-digit LCD with a bar graph (Red for positive, Blue for negative) ✅ Review: Pros & Cons Precision Targeting: The LED guide rings ensure you aren't guessing the distance, which is critical for accurate kilovolt readings. Compact & Portable: It is lightweight and fits easily in a pocket or toolkit for floor inspections. Ionizer Testing: With an optional metal plate, it can measure ion balance (offset voltage) up to plus or minus 200 Data Hold: The "Hold" button allows you to freeze a reading, which is useful when measuring in tight spaces where you can't see the screen. Micro Precision Calibration Legacy Model: Finding new units is difficult; most available on sites like are "used" or "refurbished". Limited Range: Modern versions like the FMX-004 offer a higher range (up to plus or minus 30 kV) compared to the FMX-002's plus or minus 20 Calibration Needs: As a precision instrument, it requires annual recalibration to maintain accuracy. 💡 Pro-Tip for Use ground the case before measuring. The conductive plastic housing and ground snap are designed to ensure your body’s own static doesn’t interfere with the sensor's readings. Ubuy Pakistan If you're looking for the full manual current pricing , I can find: PDF download link for the instruction manual best current price for a used FMX-002 vs. a new FMX-004 step-by-step guide on how to perform a zero-adjustment Let me know which SIMCO FMX-003 Electrostatic Field Meter Pakistan | Ubuy

Simco FMX-002 Electrostatic Fieldmeter Go to product viewer dialog for this item. is a legacy, high-precision instrument used in industrial and laboratory environments to measure the strength and distribution of electrostatic charges. While it has largely been succeeded by models like the FMX-003 and FMX-004, its core operation remains the foundation for static measurement in many facilities. The Story of a Measurement: Using the Go to product viewer dialog for this item. Imagine a high-stakes electronics assembly floor. To ensure safety and quality, a technician must verify that a surface is free of dangerous static buildup. Preparation : The technician first ensures the device is properly grounded using the ground snap on its conductive case. They then press the POWER button; a single beep confirms the internal micro-computer is ready. Calibration (Zeroing) : Before approaching the test object, the meter is pointed toward an uncharged area (like a grounded metal surface). The technician presses the ZERO button to calibrate the digital display to "0.00," ensuring the measurement starts from a true neutral point. The Approach : Moving the meter toward the target, two LED guide ring lights emerge. These beams are the "aiming sights"—when they merge into a single concentric circle on the surface, the technician knows they are at exactly one inch (25mm) away, the precise distance required for an accurate reading. The Reading : The display instantly reveals the invisible. A digital numeric value and a color-coded bar graph appear— red for positive polarity and blue for negative. If the display is in a hard-to-see spot, the technician hits the HOLD button to freeze the data before pulling the meter away to record it. Completion : With the task done, the technician powers down. If they forget, the device's Auto-Off feature will beep and shut down after five minutes to save the 9V battery. Key Specifications at a Glance Description Measurement Range Low range (0 to ±1.49 kV) and High range (up to ±20 or 30 kV depending on specific revision) Accuracy High precision (typically ±10%) for industrial quality assurance Portability Lightweight (approx. 6 oz) and pocket-sized for easy maneuverability Distance Guide Dual LED focusing lights for a perfect 1-inch measurement gap Simco FMX-002 Electrostatic Fieldmeter Calibration

The Simco-Ion (and its successor, the ) is a handheld electrostatic fieldmeter used for locating and measuring static charge potentials. Quick Setup & Operation : Press the Distance Alignment : Point the sensor at the target. Align the two LED guide ring lights until they converge into a single circle on the surface to ensure the correct measuring distance of Point the device at a known grounded (earthed) surface. Press the grey Note: Zeroing won't work if the [HOLD] function is active or the current value is >50V Hold Feature to freeze the current measurement on the digital display for easier reading. www.joongang21.com Ion Balance Measurement (Optional) Install Plate : Depress the release buttons on the side to attach the metal ion balance plate assembly to the end with the SIMCO logo. : Press the button to switch to ion balance mode (measures up to : Ensure the instrument is connected to the earth using the supplied grounding lead for accurate readings. www.joongang21.com Maintenance Tips : Replace the 9V battery when the indicator shows low power. Open the rear cover, ensuring correct polarity. Environment : For reliable results, use in environments where relative humidity does not exceed : Remove the battery if the device will not be used for an extended period. www.joongang21.com troubleshooting common error codes? FMX – 003 simco fmx002 manual top

The Simco FMX-002 Go to product viewer dialog for this item. is a portable electrostatic fieldmeter used for locating and measuring static charges in industrial environments. While newer models like the FMX-004 have largely succeeded it, the remains a reliable tool for non-contact measurement of surface voltages. Key Features & Operation Measurement Range : It detects static charge potentials up to ±19.99 kV at a standard distance of 25mm. LED Guide Lights : Two LED "guide rings" converge into a concentric circle when the meter is held at the correct 25mm (1 inch) distance from the target surface. Display : Features a color-coded bar graph (Red for positive, Blue for negative) and a digital 3-digit readout. Control Buttons : Simple interface with Power, Zero (to tare the reading), and Hold buttons to freeze a measurement on the screen. Ion Balance Mode : By attaching an optional metal plate, it can measure ionizer balance (offset voltage) up to ±200V. Best Practices for Use Zeroing the Meter : Always press the "Zero" button in a static-free area before starting your measurement to ensure accuracy. Distance Accuracy : Use the converging LED lights to maintain the exact 25mm distance; improper distance will result in incorrect voltage readings. Grounding : For the most accurate measurements, the user should be grounded or hold the conductive plastic housing firmly. Maintenance : Clean the sensor regularly with a soft, dry cloth. Avoid touching the sensor directly, as it is highly sensitive. Support & Resources Manuals : Official instruction manuals for similar current models, like the FMX-004 Manual, provide relevant safety and operation guidance that applies to the older Calibration : Manufacturers like Micro Precision offer specialized calibration services to ensure the device meets industrial accuracy standards. Replacement Parts : Used units and accessories are occasionally available through industrial liquidators on platforms like eBay . FMX-004 - Simco-Ion 1. SAFETY WARNINGS. Simco-Ion recommends that these instructions be read completely before installation or operation is attempted. Simco FMX-002 Electrostatic Fieldmeter Calibration

The Simco FMX-002 is a legacy handheld electrostatic fieldmeter designed for the accurate measurement of static voltages. While newer models like the FMX-003 and FMX-004 have since been released, the FMX-002 remains a reliable tool in many electronics manufacturing and cleanroom environments. This manual overview covers the essential technical specifications, operational procedures, and maintenance tips to ensure your device provides precise readings. Technical Specifications and Features The Simco FMX-002 is engineered for portability and ease of use. Understanding its core capabilities is the first step toward effective static monitoring: Measuring Range: 0 to ±1.49 kV (Low range); ±1.0 kV to ±20.0 kV (High range). Accuracy: Within ±10% of the measured value. Distance Indicator: Integrated LED focus lights (red circles) ensure the device is held at the required 1-inch (25mm) distance. Display: A clear LCD screen featuring a bar graph and digital numerical readout. Power Source: 9V battery, providing approximately 30 hours of continuous operation. Operational Guide: Step-by-Step To get the most out of your Simco FMX-002, follow these standard operating procedures: Powering On and ZeroingPress the "POWER" button once. Before taking a measurement, you must zero the meter to account for ambient static. Aim the sensor at a grounded surface or into the air away from charged objects and press the "ZERO" button. The display should read 0.00. Positioning the MeterHold the meter exactly 1 inch (25mm) away from the surface you are testing. Use the two converging red LED beams; when the two circles overlap to form a single bright ring, you are at the correct distance. Reading the DisplayThe bar graph shows the polarity (positive or negative) and the approximate magnitude of the charge. The digital display provides the specific voltage. If the charge exceeds 1.49 kV, the meter will automatically switch to the high-range mode (multiplied by 10). Data Hold FunctionIf you are measuring in a hard-to-reach area, press the "HOLD" button. This freezes the current reading on the screen, allowing you to pull the meter away and record the data. Maintenance and Calibration Because the FMX-002 is a precision instrument, regular upkeep is vital for safety and compliance in ESD-sensitive areas: Battery Replacement: A flashing battery icon indicates low power. Always use high-quality alkaline 9V batteries to prevent leakage. Sensor Protection: The sensor plate is delicate. Never touch it with your fingers or cleaning tools, as oils and physical pressure can permanently damage the sensing element. Cleaning the Case: Use a soft, lint-free cloth dampened with a mild detergent solution. Avoid harsh solvents like acetone or thinners. Annual Calibration: To maintain industry standards (such as ANSI/ESD S20.20), the unit should be calibrated annually by a certified laboratory to verify its accuracy against NIST-traceable standards. Troubleshooting Common Issues Erratic Readings: This often occurs if the device is not properly grounded. Ensure the operator is wearing a grounded wrist strap or that the meter's conductive case is being held by a person standing on a dissipative floor. No Power: Check the battery orientation or replace the battery entirely. Ensure the battery contacts are clean and tight. Constant "Over" Message: The static charge may be higher than 20kV. Move the meter further away to see if a reading appears, but note that the numerical accuracy is only valid at the 1-inch focal point. By following these manual guidelines, users can ensure their Simco FMX-002 provides the critical data needed to maintain an ESD-safe workplace and protect sensitive electronic components from catastrophic static discharge.

Mastering Your Static Measurements: Top Tips for the Simco FMX-002 Static electricity is a silent disruptor in manufacturing, leading to product damage, dust attraction, and safety hazards. If you are using the Simco FMX-002 Electrostatic Fieldmeter , you have a reliable tool for locating these hidden charges. To ensure you get the most accurate readings every time, here are the top operational "pro-tips" straight from the manual's best practices. 1. The Magic Distance: 25mm (1 inch) The FMX-002 is calibrated specifically for a distance of 25mm (roughly 1 inch) from the target surface. The LED Guide Rings: The device features two LED guide lights. Move the meter toward the surface until these two circles of light overlap into a single ring. This ensures you are at the exact calibrated distance for an accurate measurement. 2. Zeroing for Accuracy Before every measurement session, you must "zero" the meter to clear any residual charges. How to Zero: Point the sensor away from charged objects (ideally toward a known grounded surface) and press the gray ZERO button. Troubleshooting: Note that the zero button will not function if the device is in HOLD mode or if the current reading is already too high, indicating the sensor is already near a strong charge. 3. Understanding the Display The FMX-002 utilizes a dual-display system to give you both instant and detailed feedback: The Bar Graph: Provides a quick visual of the charge polarity— Red indicates a positive charge, while Blue indicates a negative charge. Digital Readout: Shows the precise voltage. The device features Auto-ranging , meaning it will automatically switch between low-voltage (0–1.49 kV) and high-voltage (up to 20.0 kV) ranges. 4. Use the "HOLD" Function in Tight Spaces Measuring static in a deep machine pocket or a cramped assembly line can make it hard to see the screen. Press HOLD (Green Button): This freezes the current measurement on the display. You can then pull the meter out of the tight space to read the value comfortably. 5. Beyond Static: Ion Balance Testing One of the "hidden" manual features of the FMX-002 is its ability to check Ionizer Balance (offset voltage). By attaching a specific metal plate, you can measure up to +/- 200V to ensure your ionizers are operating correctly and not creating their own charge imbalances. Quick Specs at a Glance Measurement Range: Up to +/- 20.0 kV. Response Time: 1 second. Power: Runs on a standard 9V battery, typically lasting about 30 hours of continuous use. You can find detailed calibration services and support via Micro Precision or consult the official Simco-Ion documentation. Simco FMX-002 Electrostatic Fieldmeter Calibration Core Functionality and Measurement The FMX-002 is primarily

Simco FMX-002 (also known as the Simco-Ion FMX-002) is a portable, non-contact digital electrostatic fieldmeter used to measure static charges. It features a compact design with two LED guide lights to ensure the correct measuring distance. Key Controls and Operation The device is operated via four main push-button controls: : Turns the unit on/off. A single beep typically indicates power-on. To bypass the Auto Power-Off (5-minute timer), hold the power button for more than 3 seconds until you hear three beeps. : Resets the display to zero. This should be done while pointing the sensor toward a grounded or uncharged area. : Freezes the current reading on the display, which is useful when measuring in hard-to-see areas. MODE / Ion Balance : Switches the unit between standard electrostatic field measurement and Ion Balance mode. Measurement Instructions Preparation : Ensure the unit is properly grounded using the provided ground cord connected to the side jack. Distance Alignment : Point the sensor at the target surface. Adjust the distance until the two LED guide beams overlap to form a single concentric circle. This indicates the standard 1-inch (25mm) measuring distance. : 0 to ±1.49 kV. High Range : ±1.0 kV to ±20.0 kV. : The bar graph shows red for positive polarity and blue for negative polarity. Ion Balance Measurement To measure the offset voltage of ionizers: Plate Installation : Attach the metal ion balance plate to the sensor end of the device. Activation simultaneously (or the button on some variants) to enter Ion Balance mode. Measurement : Ground the plate first to clear any charge, then hold the device in the ionized airflow. The range for this mode is typically 0 to ±200V. Maintenance and Troubleshooting Simco-Ion FMX-004 Tutorial Jun 5, 2014 SIMCO Japan - FMX002 Fieldmeter

Simco FMX-002 is a legacy, highly regarded handheld electrostatic fieldmeter used primarily in electronics manufacturing, cleanrooms, and automated industrial environments to locate and measure static charge potentials. Below is a comprehensive technical write-up based on its manual operations, top interface features, and practical applications. 1. Overview and Key Specifications is engineered to measure static voltages up to . It utilizes a non-contact measuring method and features a physical design meant to be easily grounded through its conductive plastic casing and ground snap. device.report Primary Measurement Range: (low range) and (high range). Ion Balance Mode: Capable of measuring offset voltages up to when used with the attachable metal plate. Target Distance: ), guided by a specialized dual LED ring system. Power Source: alkaline battery. 2. Top Interface and Button Layout The user interface on the top of the focuses on extreme simplicity, allowing operators to execute operations blindly while focusing on the target surface. The layout typically features a large digital LCD screen accompanied by three core tactile push buttons POWER Button: Turns the unit on or off. A single press initiates the standard electrostatic field measurement mode. ZERO Button: Used to zero out the device before taking a reading. To avoid false zeroing, the device will generally reject a zero command if the sensor is already detecting a field greater than a specific threshold (e.g., ) or if the display is currently frozen. HOLD Button: Freezes the current reading on the LCD. This is critically useful when reaching into cramped machinery or awkward angles where the screen cannot be actively monitored by the operator. Visual Indicators on the LCD: Dual-Color Bar Graph: Usually shows red for positive static charges and blue for negative charges. Digital Readout: A 3-digit active display that auto-ranges depending on the field strength. Battery Capacity & Error Prompts: Displays the real-time battery status and flags an prompt if the precision sensor has been compromised. device.report 3. Step-by-Step Operating Procedures A. Electrostatic Field Measurement Grounding: To ensure safe and highly accurate readings, connect the grounding lead from the side ground snap of the device to an earth-grounding point. Zeroing the Sensor: Point the sensor at a known grounded or non-charged surface and press the button until the reading shows Targeting: Move the sensor toward the object being measured. Watch the two projected LED guide rings on the surface of the object. Slowly move the device closer or further away until the two light rings converge into a single, perfectly focused ring. This indicates you are at the exact required measurement distance of Read or Hold: Note the reading on the display, or press to freeze the data before pulling the unit away. device.report B. Ion Balance Measurement (For Air Ionizers) Mount the detachable metal plate over the sensor front according to the manual. button and access the ion balance mode (labeled as or toggled via mode buttons depending on exact regional sub-iterations of the 002/003 series). Hold the plate in front of the airflow of the ionizer to measure its offset voltage performance up to (Note: The distance-indicating LEDs do not turn on during Ion Balance mode). device.report 4. Critical Maintenance and Safety Notes Sensor Care: The sensor at the top is incredibly sensitive. Never touch the sensor grid or stick objects inside the aperture. Auto Power-Off: To conserve battery life, the will automatically turn off after roughly of idle state. Humidity Constraints: For highly reliable and repeatable metrics, measurements should generally be carried out in environments where the relative humidity does not exceed www.joongang21.com calibration interval recommendations for the FMX series or compare this legacy model to the upgraded SIMCO FMX-003 Electrostatic Fieldmeter Instruction Manual

Simco FMX002 — Quick Post / Manual Summary Product: Simco FMX002 (ionizing air blower / static eliminator — assumed model) Top-line use Operational Procedures Effective use of the FMX-002 requires

Position unit 150–600 mm (6–24 in) from the target surface for best neutralization. Aim airflow evenly across charged surface; adjust fan speed to balance coverage vs. ion decay time. Use in clean, dry environments; avoid direct contamination of emitter points.

Setup