Menu Close

Mac Tools Et97 User Manual ((top)) ★ < TESTED >

The ET97 beeped. A new option appeared:

This section includes a detailed diagram. You will learn the function of every button, jack, and symbol: Mac tools et97 user Manual

| Problem | Likely Cause | Solution per Manual | | :--- | :--- | :--- | | | Dead 9V battery or open fuse | Replace the battery. If still dead, check the internal fuse near the battery terminals. | | Inaccurate resistance reading | Test leads have resistance; low battery | Use the REL mode to zero out lead resistance. Replace the 9V battery. | | No continuity beep | Meter not in continuity mode; blown fuse | Ensure the rotary switch is on the continuity symbol (not ohms). Check the mA or A fuse. | | “OL” on display | Overload; measurement out of range | Select a higher range (if manual ranging) or check if the circuit is open (for resistance). | | Fluctuating voltage reading | Low battery; dirty test leads; EMI | Replace battery, clean leads, move away from motors or VFD drives. | The ET97 beeped