Invt Che100-0r7g-s2 Manual

The output of the CHE100-0R7G-S2 is three-phase 220V . It is designed to control a three-phase induction motor, not a single-phase motor. Attempting to run a single-phase motor without derating will damage the drive.

The INVT Che100-0R7G-S2 is a high-performance variable frequency drive (VFD) designed for industrial applications. This manual provides a detailed guide on the installation, operation, and maintenance of the INVT Che100-0R7G-S2 VFD. Please read this manual carefully before using the device to ensure safe and efficient operation. invt che100-0r7g-s2 manual

: Specific fault codes and maintenance procedures to ensure long-term reliability. The output of the CHE100-0R7G-S2 is three-phase 220V

OC1 / OC2 / OC3 (Overcurrent): Check for a motor short circuit, heavy mechanical load, or if the acceleration time (P0.11) is too short.OV1 / OV2 / OV3 (Overvoltage): Often occurs during rapid deceleration. Increase deceleration time (P0.12) or install a braking resistor.UV (Undervoltage): Check the input power supply for stability or a loose connection.OL1 / OL2 (Overload): The motor or drive is being pushed beyond its current rating. Check for mechanical jams or reduce the load.OH (Overheat): Ensure the cooling fan is running and that there is sufficient airflow around the heat sink. Safety Precautions : Specific fault codes and maintenance procedures to